Abstract

Skinfold caliper measurements are routinely utilized in assessing individual’s body composition and subcutaneous fat thicknesses. The precise separation of subcutaneous fat from muscle is critical to obtaining accurate measurements of body composition. The current investigation examined the accuracy of a flexed skinfold method (FSM) compared to the traditional relaxed skinfold method (RSF) and DEXA in 20 males (mean age = 20.8 + 2.5 yrs) and 20 females (mean age = 20.8 + 1.6 yrs). Body composition was assessed by FSM and RSF in a counterbalanced design within gender for RSF and FSM, using Lange skinfold calipers with the Jackson-Pollock 3-site method and the Siri’s percent body fat equation. Each site (chest, umbilical, and thigh for males; triceps, super iliac, and thigh for females) was measured three times and the average was utilized to calculate body density and percent body fat. The same researcher performed all skinfold measurements and DEXA scan on a single occasion. A 2 X 3 ANOVA was used to determine the effect of gender (females and males) and different body composition methods (FSM, RSM, and DEXA) along with Bland-Altman plots. No statistical differences were observed between FSM and RSM in body fat percentage (FSM: 15.7 + 7.5% vs. RSM: 16.0 + 7.5%; p = 0.74), chest (FSM: 4.3 + 1.2mm vs. RSM: 4.6 + 1.6mm; p = 0.83), triceps (FSM: 18.7 + 6.1mm vs. RSM: 18.6 + 5.4mm; p = 0.52), super iliac (FSM: 15.2 + 4.3mm vs. RSM: 15.1 + 4.8mm; p = 0.62), or umbilical measurement (FSM: 17.1 + 6.3mm vs. RSM: 17.3 + 6.2mm; p = 0.62). However, there was a significant difference in thigh skinfold location, indicating that subcutaneous fat measured by FSM was lower than one measured by RSM (FL: 17.5 + 7.2mm, RL: 18.5 + 7.4mm; p = 0.003). Additionally, both FSM and RSM underestimated body fat percentage as compared to DEXA (FSM: 15.7 + 7.5%, RSM: 16.0 + 7.5%, vs. DEXA: 18.9 + 7.5%; p < 0.01). It appears that assessing overall body composition using a flexed skinfold method does not necessarily improve the overall accuracy of skinfold body composition measurement when compared against a relaxed method.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.