Abstract

To minimize the effect of shifts in bodily water compartments, assessments of resistance (R) and reactance (Xc) via bioelectrical impedance analysis (BIA) is recommended to occur after the individual has been supine for 15 minutes. While changes in bodily water compartments within 15 minutes of laying in the supine position may affect values for R and Xc, it’s unknown how these body water shifts affect phase angle (PhA). PURPOSE: Investigate the effect of time for stabilization of supine measurements of R, Xc, and PhA obtained via the RJL Quantum Legacy BIA analyzer. METHODS: Thirty-eight men (n=16) and women (n=22) were deemed hydrated (urine specific gravity ≤1.020) and were prepped for standard tetrapolar electrode placement. In the supine position, R, Xc, and PhA at 50kHz were measured on the right side of the body immediately after laying down (baseline) and every 5 minutes for 15 minutes. Participants remained motionless throughout the duration of the test. Separate one-way repeated measures ANOVA were used to assess the effect of time on R, Xc, and PhA. For repeated measures ANOVA comparisons, generalized eta squared (η2G)was reported to quantify the observed effect size, where small = .01; medium = .06; large = .14. An alpha of .05 was used to determine statistical significance. RESULTS: There was a small but significant effect of time on R, F(1.76, 65.16) = 74.091, p < .001, η2G < .001. Average values for R increased from 553.2 ± 90.1Ω at baseline to 560.4 ± 93.3Ω post-15 minutes. A small but significant effect for time on Xc was also observed, F(1.34, 46.01) = 20.958, p < .001 η2G = .004. Average values for Xc increased from 68.2 ± 7.8Ω at baseline to 69.6 ± 8.1Ω post-15 minutes. Laying in the supine position for 15 minutes had no significant effect on PhA, F(1.2, 44.51) = 3.401, p = .065, η2G < .001. Average PhA values went from 7.13 ± .90° at baseline to 7.18 ± .86° post-15 minutes. CONCLUSION: While time to allow for bodily water compartment stabilization has a small but significant effect on R and Xc, this study demonstrates that PhA is likely unaffected. PhA can be accurately assessed immediately upon assuming the supine position without allowing for bodily water compartment stabilization via the RJL Quantum Legacy.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.