•  
  •  
 

Abstract

The utility of wearable activity monitors can provide a better guide to increase adherence to the recommended physical activity levels for health improvement. However, the extent of participants’ ability to comply with the physical activity prescription using a newly developed, intensity-focused value, real-time cadence, remains unclear. PURPOSE: To examine the participants’ ability to comply with a given physical activity prescription focusing on intensity (i.e., real-time cadence). METHODS: Thirty-six healthy adult individuals (age 18-65 yrs; 18 female) participated in the study. During a 2-min over-ground walking trial, participants were prescribed to walk at any cadences (steps/min; an indicative of intensity of ambulatory activities) faster than 120 (i.e., equivalent to a brisk walking) using either one of the following devices in a counter-balanced order: (1) Garmin Forerunner 235 (GM) and (2) Polar M430 (PL), (3) Garmin Foot Pot (FP) and (4) Polar Stride Sensor (SS). Descriptive statistics were used to calculate the % of participants who complied accordingly with the given physical activity prescription as well as the means of cadence performed in each trial. Pearson correlation was conducted to determine the relationship between a criterion (i.e., hand count) and the measures from each device. RESULTS: In general, greater than 90% of the participants (91.7%, 97.2%, 100%, and 97.2% for the device (1) through (4), respectively) were able to maintain walking intensity at the prescribed level using real-time cadence. Mean cadences performed in the protocol were barely above the prescribed intensity, 120 steps/min (i.e., approximately 123 steps/min). The correlations showed strong relationships between the criterion and the measures of the monitors (p <.001). GM and PL sometimes showed a value of zero (0), indicating no detection of steps, during the protocol (from 4 and 11 participants, respectively). CONCLUSION: The results suggest the potential to use the activity monitors providing real-time cadence for physical activity prescription and clarify the participants’ capability to manipulate the values of real-time cadence to maintain the targeted intensity of physical activity. A highly aimed intensity prescription rather than minimum requirement might help individuals ensure the compliance with targeted intensity.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.