•  
  •  
 

Abstract

Many smartphone applications available promote exercise engagement, specifically in short bouts of time. One such application “The 7-minute workout challenge” promotes a brief exercise bout, however details on the potential cardiometabolic health benefit is lacking. Purpose:To investigate the acute cardiometabolic responses of a 7-minute body-weight resistance exercise circuit (HICE) compared to a 7-minute high intensity interval training cycle protocol (HIIE). Methods: Apparently healthy and active young adults (N=12, 50% Female, 24.0±3.4 yr, BMI: 28.1±6.4 kg/m2) were enrolled in a randomized crossover study (HICE vs HIIE). The 12 HICE exercises were 30 seconds each using a standardized cadence, followed by a five-second transition period between followed by a three-minute cool-down and was replicated in the HIIE protocol. The HIIE protocol used cycling at 70 RPM at predetermined power output that elicited a heart rate response of 70-80% of HR max using a similar 30:5 second exercise to rest ratio. Following each protocol, subjects were seated for the next hour. Measurements included blood pressure (BP) and heart rate, taken prior to exercise, immediately after, 15, 30, 45, and 60-minutes post-exercise, and blood glucose and blood triglycerides taken only prior to exercise, immediately after and at 60-minutes. General mixed linear modeling was used to analyze the data (p≤0.05) and Cohen’s dwas calculated for effect size. Post hocanalysis of individual time points used Bonferroni adjustment. Results: There was no significant difference in overall systolic BP between HIIE and HICE (b= 1.639 mmHg, p=0.168, d= 0.213). However, there was a significant difference in overall diastolic BP resulting a higher response in HIIE (b= 2.273 mmHg, p=0.002, d= 0.436). Immediately after exercise (b= 5.018 mmHg, p=0.001, d= 0.962) and at 15 minutes (b= 3.945 mmHg, p=0.018, d= 0.756) exhibited significant and trending, respectfully, higher values in diastolic BP for HIIE. The overallpost-exercise heart rate was lower for HIIE vsHICE (b= -8.955 bpm, pd= -0.857). Furthermore, all individual time points (b= -5.737 to -11.791 bpm, pd³0.549) except for 45-min post-exercise HR were significantly lower in HIIE vsHICE. Blood glucose had no overall difference between the two protocols (b= -0.200 mmol/L, p=0.104, d= 0.480). Triglycerides had no overall difference on HIIE vsHICE (b= 0.014 mmol/L, p=0.966, d= 0.007). Conclusion:The HICE protocol had a similar cardiometabolic response post-exercise to HIIE, but did have a reduction in diastolic BP post-exercise. However, post-exercise heart rate was higher. Future research should investigate the potential blood pressure benefit of using such an application utilizing body-weight resistance exercises for multiple time points across a single day or multiple days.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.